Tight House
Problems
The Consumer Federation of
America cites that indoor air pollution is responsible for up to 50% of all
illness. Estimated cost in medical bills and lost work time amount to over
$100 billion annually.
The American Medical Association has stated that with the reduction of
fresh air entering a home, increased levels of Radon gas and other
know carcinogens have been detected. The pollutants are know to cause serious
health problems.
Indoor air quality, or lack of it, can be identified by
the three "B's" of
ventilation. The first "B" is breathing. Consider all of the
people and pets breathing in air and out carbon dioxide. Each
breath reduces the amount of oxygen that is available within the house. If the
house is tight then the oxygen content will lessen and air quality will
deteriorate.
The second "B" is blowing.
Take into consideration all the
fans within the house, bathroom, kitchen, clothes dryer, central vacuum, power
vented furnace or water heater each of these blows air out, not one is
designed to bring air in to balance itself. Too much air being blown out of a
house can lead to depressurization. Smoke escaping from a wood stove
is one
indication that your house is being depressurized. Few people realize that
they have a down draft problem but freely admit to having that nice woodsy
aroma. That nice woodsy aroma turns to a nasty creosote smell in the early
hours of the morning.
The third "B" is burning and concerns all of the appliances
that heat or involve the combustion process. These appliances include a
furnace, water heater, fireplace,
woodstove, cooker, toaster and toaster oven. When these appliances are
working they simply burn up the oxygen again reducing the amount available for
breathing. If you leave a fireplace
burning,
in the early hours of the morning, when the fire is nearly out and the furnace
comes on, there is enough draw up the furnace flue to reverse the flow in the
fireplace
chimney, thereby creating a downdraft and the nasty smell associated with it.
This can also work in reverse where furnace fumes can be drawn out of a flue
by a briskly burning fire, these fumes are dangerous and could lead to carbon monoxide
poisoning.
If your house is closed up and does not have adequate ventilation, when
morning comes you can actually smell the residue from the wood fire or the
previous days activities, couple these with the household chemicals and the
off gassing from furniture and carpets and you can see that you are living in
a soup of low pressure polluted air. The easy answer is to open a window in
each room however this solution is not always practical since the air coming
in will be cold and your heating bills will go up very quickly. Obviously you
need fresh air but in a controlled fashion and at the lowest possible cost.
What is required is a ventilation system that is able to supply warmed fresh
air, be able to compensate for negative air pressures, supply combustion air
at a place and time when needed and be cheaper to run than opening a window.
Fortunately the US Plusaire®
system was designed to do exactly that.

To the Top
Fireplaces, wood
stoves and inserts sometimes experience back drafting. This is generally blamed
on the wind or the chimney not being high enough. To really solve the problem first it has to be correctly defined.
Smoke or fumes come out of the heater when the door is opened, or the fire
is difficult to light because of cold air coming down the chimney. In most
cases it's because the house is at a lower pressure than outside and the air
is being sucked backwards down the chimney. The problem can be worse when it's
windy so generally the wind gets the blame. There is a name for this
phenomena, it is called Stack Effect.
Stack Effect is occurring because the house is acting as a better chimney
than the chimney. All of the air within the house is warmer and more buoyant than the air outside and therefore wants to rise. If there is an opening in
the uppermost part of the house then the warm air will find it and leak
outwards. This creates a powerful draw in the lower part of the home pulling
cold air in through the easiest opening; the chimney. The areas that leak in
the upper most parts of the house are the attic access hatch, ceiling light
fixtures, and poorly fitting windows. Each of these areas can be reworked to
stop the air leaks. By doing this it will not only reduce the Stack Effect but
your heating bills will also be reduced. What cannot be changed are the
various exhaust fans that blow air out of the house. These can create a Stack
Effect which can only be corrected by adding air to the house to balance the
air that is being blown out. The cure to Stack Effect is therefore a
combination of adding adequate ventilation air and sealing the leaks in the
upper most areas of the house. Sealing air leaks only in the basement can
aggravate the situation.
Remember for every cubic foot of air that leaves a house, a cubic foot of
air must be brought in to replace it.
A US
Plusaire®
will handle the ventilation and combustion air, the other
measures can be easily corrected by the homeowner.

To the Top
Carbon monoxide (CO) is called the silent killer or the
silent threat. This is because it is colorless, odorless, and silent. It is
formed as a by-product of combustion of carbon based fuels such as natural
gas, propane (LPG), coal, coke, furnace oil, kerosene and wood. Carbon
monoxide is absorbed by breathing and is 245 times more absorbent to the body
than oxygen. Symptoms of poisoning can be misdiagnosed as flu since they are
very similar.
-
Dizziness and blurred vision
-
Nausea and vomiting
-
Confusion, weakness of muscles
-
Insomnia and constantly tired
-
Chest pain
-
Fainting
-
Cherry colored skin
High concentrations of 4000 parts per million can kill in minutes but
lesser amounts can produce any or all of the above symptoms. A level of nine
parts per million is reckoned to be the maximum safe level over 24 hours which
is very little so you can see just how deadly it is. It is highly recommended
that CO detectors be installed in your home at places recommended by the
manufacturer. These detectors can be purchased for around $30, a small price
to pay for protection.
The appliances that can generate CO within your house are the furnace,
boiler, water heater, un-vented fuel burning heaters and solid fuel burning
appliances. The three main problems are improper installation, chimney or vent
blocked by bricks or birds nests etc. and inadequate ventilation, providing
insufficient air to properly fuel the combustion process.
Improper installation can be easily checked by referring to the
manufacturers installation instructions and by having your heating system
checked yearly by a qualified professional. A flue system should be checked by
a professional at the beginning and end of each burning season and cleaned
accordingly. A flue that is in poor condition will be easily spotted and the appropriate
action taken prior to disaster.
Supplying adequate combustion air is very simple. A window opened in the
room of the appliance is a good, cheap method but not too practical since it
will allow cold air in unless you close it when the appliance goes off. A
better solution is a US Plusaire®
correctly sized for the house. It will supply
not only adequate combustion air but also ventilation air to compensate for
any of the exhaust fans that tend to depressurize the house.

To the Top
Radon is the second leading cause of lung cancer.
Radon is an odorless invisible gas that is produced naturally by the decay
of the element of uranium. On average about six atoms of Radon emerge from
every square inch of soil per second. In the air Radon is diluted to about 2 Pico curies
per liter of air which is not dangerous but in concentrations it
has been found to cause lung cancer.
Radon gas can enter a house through a soil floor or through any crack or
hole in or around the basement.
Since prevention is better than cure it would be wise to prevent any Radon
from concentrating within the house. This can be done in two ways:
First, by sealing up any crack or hole in the basement wall and covering
any earth floor with plastic sheeting. There are companies that specialize in
Radon protection sealing.
The second is to increase the ventilation in the house so that
concentrations cannot build up. All houses should have a complete air change
every three to four hours. This level of air change has been found to be the
most economical balancing air quality with heating costs.
Supplying adequate air is very simple. A window opened in each room is a
good, cheap method but not too practical since it will allow cold air to
enter. A better solution is a US Plusaire®
correctly sized for the house.
It will supply not only adequate ventilation air but also combustion air to
compensate for any of the combusting appliances that burn up the oxygen in the
house.

To the Top
In the mid 1970's new houses
were constructed and were advertised as being energy efficient. This trend has
grown to the present. Now the houses are so energy efficient that some people
boast of $300 yearly fuel bills. Building an energy efficient home really
meant using better built windows and doors and sealing up the structure to
stop the outside air from leaking in and the inside air from leaking out.
Unfortunately what was not apparent was that the older houses had air leaks
which supplied combustion and ventilation air. What was starting to happen was
that the energy efficient houses were becoming tighter and indoor air quality
was deteriorating as a result. The tighter the house the worse the condition.
Combustion and ventilation air is not able to infiltrate into the house and
combustion devices are being starved of air. There is no replacement air for
the exhaust fans to blow out which causes the house to depressurize.
Depressurizing a house can lead to a new set of problems including carbon monoxide
poisoning. The problem is not confined to new houses.
Anyone who has renovated with a few tubes of caulking, new windows, doors
or siding, has changed the air infiltration rate. In every case the cost of
heating would be less, but, tightening up the structure, without considering
the need for combustion or ventilation air, can invite disaster.
Symptoms of a too tight house are condensation on the windows, smoke
escaping from the fireplace or wood stove, mould or mildew growing in corners
or cupboards, residual smoking or cooking odors and a general stale smell
especially in the mornings. Another common sign is a high humidity level that
cannot be corrected.
While these symptoms are unpleasant and undesirable, symptomatic health
problems can be far serious. Constant headaches, dizziness, sleepiness, watery
eyes, breathing difficulties and in some cases death can be attributed to
houses with poor air. Most susceptible are the very young and the elderly.
Asthma sufferers and people with allergies are especially susceptible to poor
quality air.
Since the tightness of the house is causing the health problems then it
follows that if the house is made less tight then related health problems will
also cease. The common thread linking all of these symptoms together is the
lack of ventilation, and this can be verified quite easily by following some
simple steps. Begin by opening a window about 1", on each floor. Leave the
windows open for 24 hours or until the house symptoms are gone and then close
the upper most window each day until the symptoms reappear. This test requires
very little effort and will only cost some heat. Measure the amount of opening
that is left and that is the amount of opening that must be provided in the
outside wall. This test will verify that you have a lack of ventilation air.
The simplest form of adding ventilation and combustion air is to keep the
windows open but since the air coming in would be freezing cold it is not too
practical. What is required is a device that brings in outside air, warms it,
delivers it around the house and is as cheap to operate as opening a window. A
US Plusaire®
correctly sized for the house is such a device.

To the Top